Guide · Updated October 2026

Vaillant fault codes: F.75, F.28, F.22 and how to reset your boiler

The short answerA Vaillant fault code tells you why the boiler has locked itself out. F.75 means it started its pump but didn't see the water pressure rise, F.28 means it tried to light and couldn't, and F.22 means the heating has lost water pressure. Check the pressure gauge, your gas supply and, in freezing weather, the condensate pipe, then reset the boiler. If the code returns, or three resets haven't cleared it, you need a Gas Safe registered engineer.
A Vaillant boiler with its case on and a flue gas analyser connected during a service visit

Before you press reset: what you can check

Vaillant's advice is to sort out the cause before you reset. The checks a homeowner can safely make take a couple of minutes:

  • Write the code down, along with the model name on the front of the boiler. It's the first thing an engineer will ask for.
  • Look at the pressure gauge. Vaillant's normal range is 1 to 1.5 bar with the heating cold. Below 1 bar, it needs topping up with the filling loop: how to repressurise a boiler explains the steps.
  • Check the gas. Does the hob light? If you're on a prepayment meter, is there credit? If nothing in the house has gas, the problem is the supply rather than the boiler, and it's one for your gas supplier.
  • In freezing weather, check the condensate pipe, the white plastic pipe that runs from the boiler to a drain outside. If it's iced up, thaw it with warm water from a jug or watering can. Vaillant warns that boiling water can crack the pipe.
  • Check the power and the controls: the switch and fuse for the boiler, the timer, and the thermostat setting.

Leave the casing on. Vaillant strongly advises against getting inside the boiler because it can be dangerous, and in the UK any work inside it is gas work for a Gas Safe registered engineer. If you smell gas, don't touch the boiler: call the National Gas Emergency Service on 0800 111 999.

How to reset a Vaillant boiler

The reset button is on the control panel beside the display. It usually shows a flame with a line through it.

  • Fix the cause first, using the checks above. Resetting a boiler that's still short of water or gas just brings the code back.
  • Press the reset button briefly. Vaillant's general advice is three seconds; the instructions for some models, such as the ecoFIT pure, say one second. Your manual gives the exact time for your boiler.
  • Give it a few minutes. Vaillant says some boilers take several minutes to restart, and some need a second attempt.
  • Check it's working. Run a hot tap or turn the thermostat up, and watch whether the code returns.

Stop after three tries. Vaillant's operating instructions for its ecoFIT pure and Home combi boilers say that if three resets haven't cleared an ignition fault, you should call in a competent person. And a boiler that needs resetting regularly has a fault to find, even if every reset seems to work.

F.75: the pressure didn't rise when the pump started

Each time a Vaillant starts its heating pump, it checks the reading from its water pressure sensor. Vaillant's official wording for F.75 is that the pressure change is too low when the pump starts, and the boiler stays locked out until that's put right. Vaillant lists these causes:

  • system pressure below the normal 1 to 1.5 bar
  • air in the boiler or the heating system
  • a faulty water pressure sensor
  • a faulty pump inside the boiler
  • a failed internal expansion vessel
  • a break in the wiring

What you can do: if the gauge shows less than 1 bar, top it up to between 1 and 1.5 bar, then reset. That's the one F.75 fix Vaillant says a competent homeowner can make. If the gauge already reads above 1 bar and F.75 keeps coming back, the sensor, the pump or the wiring needs an engineer.

On a recent F.75 repair in Hampstead, NW3, the culprit was a failed pressure sensor, fixed on the first visit because we brought the part with us.

F.28 and F.29: the boiler won't light, or loses its flame

F.28 is Vaillant's code for no flame being detected while the boiler tries to light; on models such as the ecoFIT pure it appears after three failed attempts in a row. F.29 means the flame went out while the boiler was running and it couldn't relight. Vaillant's causes for both start with the ones you can check:

  • Not enough gas reaching the boiler, such as low gas pressure or no credit on a prepayment meter. If F.54 shows alongside F.28 or F.29, Vaillant reads it as a fault in the gas supply.
  • A frozen or blocked condensate pipe. Vaillant names F.28 and F.29 as the codes its boilers show when the condensate pipe freezes, so in a cold snap, check it first. Once it's thawed, Vaillant suggests lagging the outside section so it doesn't happen again.
  • A faulty ignition electrode, circuit board or flue problem. These are engineer jobs.

If the hob lights, there's credit on the meter, the condensate pipe is clear and a reset still won't hold, stop there. Vaillant's own F.28 advice is that a boiler which has tried to light several times without success needs a professional.

F.22, F.20 and F.24: low pressure and overheating

F.22 is low water pressure. On an ecoFIT pure, Vaillant's instructions say the boiler switches itself off when the pressure falls below 0.5 bar, and the display then alternates between F.22 and the pressure reading. Topping up to 1 to 1.5 bar and resetting usually clears it; our boiler pressure guide walks you through the filling loop. If the gauge reads above 1 bar and F.22 still shows, Vaillant treats it as an engineer's job.

Two related codes also list low pressure among their causes. F.20 means the safety cut-out has shut the boiler down because it got too hot. Vaillant's advice is to check and top up the pressure, look for leaks and make sure the radiator valves are open; if it comes back, the pump, a valve or a blockage needs an installer. F.24 means the temperature is rising too quickly, and on a combi or system boiler Vaillant treats it as an engineer's job from the start.

Other Vaillant codes: leave these to an engineer

Vaillant's own list marks most other codes as engineer or installer jobs, with nothing for a homeowner to do but call:

  • F.0, F.1 and F.10 to F.13: a temperature sensor (flow, return, hot water or cylinder) has been disconnected or has short-circuited
  • F.23 and F.83: the flow and return temperatures aren't behaving as the boiler expects, either too far apart or barely rising when the burner lights. Vaillant's causes include air, low pressure, a pump fault and a blockage
  • F.27: a flame signal while the burner should be off. Vaillant says not to try to solve this yourself
  • F.32: a fan fault
  • F.35: the air or flue pipe is blocked
  • F.62 and F.88: problems with the gas valve or its electrical connection

Codes that start with S. aren't faults. They're status codes showing what the boiler is doing, such as S.04 (heating, burner on) or S.34 (frost protection), and need no action.

Ring us with the code, the model and what the boiler was doing when it stopped, and we'll work out the likely part before we come. Our Vaillant and boiler repairs start with a £120 visit, including up to one hour on site. If it needs parts or more work, you get a fixed price first, and £60 comes off the visit if you go ahead. We come out in the evenings too, from 5pm to 10:30pm for £159, on the same terms (evening and emergency call-outs).

More questions about Vaillant fault codes

How do you reset a Vaillant boiler?

Deal with the cause first, for example low pressure or a frozen condensate pipe. Then press the reset button beside the display, usually marked with a crossed-out flame: Vaillant's general advice is three seconds, and some of its manuals say one. Give it a few minutes to restart. If three resets haven't cleared the code, call a Gas Safe registered engineer.

What does F.75 mean on a Vaillant boiler?

Vaillant defines F.75 as the pressure change being too low when the heating pump starts. Too little water or trapped air can trigger it, and so can a faulty pressure sensor, pump or wiring. If the gauge is under 1 bar, top it up and reset. If it already reads above 1 bar, it needs an engineer.

What does F.28 mean on a Vaillant boiler?

The boiler tried to light but didn't detect a flame (on models such as the ecoFIT pure, three times in a row), so it has locked out. Check that your other gas appliances work, that a prepayment meter has credit and, in freezing weather, that the outside condensate pipe isn't frozen. If all three are fine and a reset doesn't hold, it's an ignition, gas or circuit board fault for an engineer.

What does the F.27 fault code mean on a Vaillant boiler?

F.27 means the boiler has detected a flame signal while the burner should be off. Vaillant gives a gas valve that isn't sealing properly or a faulty circuit board as the causes, and says it's a job for an expert because it can be dangerous. Don't keep resetting it: leave it locked out and call a Gas Safe registered engineer.

What are the most common problems with Vaillant boilers?

The Vaillant codes searched for most in the UK are F.75, F.28 and F.22: the pump pressure check, failed ignition and low water pressure. Vaillant's own list of common boiler problems, which applies to any make, adds leaks, frozen condensate pipes, kettling noises and boilers not responding to the thermostat. Most are repairs rather than reasons to replace the boiler.

Boiler still not right?

Call or WhatsApp for the quickest answer. Or leave your details and we’ll ring you back.

Heat exchanger being cleaned with a rotary brush during a service
Request a call backWe only use your details to reply to this enquiry.
Call now WhatsApp